[1]王农,汪夕彬.8000居里60Co辐射源铈化学剂量测定的试验报告[J].水土保持研究,1987,(02):100-104.
Wang Nong,Wang Xibin.Test Report on Measuring the Radiative Source 60Co With 8-Kilocurie by Assaying Ceric Sulfate[J].Research of Soil and Water Conservation,1987,(02):100-104.
点击复制
《水土保持研究》[ISSN:1005-3409/CN:61-1272/P]
卷:
期数:
1987年02期
页码:
100-104
栏目:
出版日期:
1900-01-01
- Title:
-
Test Report on Measuring the Radiative Source 60Co With 8-Kilocurie by Assaying Ceric Sulfate
- 作者:
-
王农, 汪夕彬
-
- Author(s):
-
Wang Nong, Wang Xibin
-
-
- 摘要:
-
本文介绍了8000居里(13000克镭当量)60Co 辐射源 Ce 化学剂量测定的原理和具体实验方法,对水的精制与纯度检验、辐照容器及其净化、应使用的仪器药品、剂量率计算公式、硫酸铈溶液的配制、铈溶液的辐照及 GCe3+值的测定、化学剂量与 PTW 万用剂量仪的比较.硫酸铈法对空心源内腔剂量的测定作了试验总结,指出本实验的最大误差为4.8%。
- Abstract:
-
If the pureness of sulfuric acid is assused,the satisactory results can be got atill by using A.R Ceric sulfate,it repeats well if the concentration of Ce4+ is 1×10-3M and the reaction amounts of Ce4+ are controlled over 30%.The maximum of relative errors was 4.8% of the dose.
参考文献/References:
[1] 钵荆量测量法:在105-10 grads下的例常应用, 《原子能快报》, 1959年, 第19, 20, 21期.
[2] 陈鹤鸣:硫酸钟剂量计, 《化学通报》, 1964年, 8期.
[3] 北京化学工业研究院九室编:《同位素在化学工业中的应用》, 中国工业出版社,
[4] 查子英:剂量测量中的化学剂量法, 《原子能科学技术》, 1964年, 7期.
[5] 安藤亘:化学剂量计的最近发展, 《同位素应用译丛》, 1966年, 7期.
[6] 洪瑞样、谢益美:硫酸亚铁法测定60Coγ射线剂量的研究, 《原子能科学技术》, 1962年.
更新日期/Last Update:
1900-01-01